CONNECTING THE INLET HOSE
The dryer must be connected to the cold water tap using
the new water supply hose. Do not use old hoses.
NOTE:
• Water supply pressure must be between 20psi and
120psi (138–827 kPa).
• Do not strip or cross-thread when connecting inlet hose
to the valve.
• If the water supply pressure is more than 120psi
(827kPa), a pressure reducing valve should be installed.
• Periodically check the condition of the hose and replace
the hose if necessary.
• Replace inlet hoses after 5 years of use to reduce the
risk of hose failure.
• Record hose installation or replacement dates on the
hoses for future reference.
1
Check the rubber seals in the inlet hose. Two rubber
seals are supplied with the inlet hose. They are used for
preventing water leaks. Make sure the connection to
the cold water tap is tight.
Hose
connector
Y connector
Rubber
seal
2
Check the installation type.
Long
hose
WITH WASHER WITHOUT WASHER
Short
hose
Y connector
Connect all water supply hoses tightly by hand and
then tighten another 2/3 turn with pliers.
WITH WASHER: When connecting the dryer to the
same faucet as a washer.
a. Shut o the cold water tap and remove the washer
hose.
b. Connect the short hose to the Y-connector.
c. Connect the other end of the short hose to the cold
water faucet.
d. Connect the long dryer hose to one side of the Y-connector
and connect the washer hose to the other side.
WITHOUT WASHER: If the dryer does not share the
cold water tap with a washer.
a. Connect the straight end of the long hose to the cold
water faucet.
NOTE:
• Before connecting the water line to the dryer, ush
several gallons of water through the hose into
a drain or bucket. This will help prevent foreign
particles such as sand and scale from clogging the
dryer inlet valve.
• Do not overtighten. Damage to the coupling can
result.
3
Connect the hose to the dryer.
Connect the water supply hose to the dryer inlet valve
tightly by hand and then tighten another 2/3 turn
with pliers. Make sure that there are no kinks in the
hoses and that they are not crushed.
4
Turn on the cold water faucet.
5
Check for leaks at the Y-connector (if used) and all
hoses.
NOTE:
• If any leaks are found, shut o the water faucet,
remove the hose and check the condition of the hose
washer.